8-36
Installation and Maintenance
V
olume
Octel Overture 200/300 Serenade 3.0
PB60014–01
Table 8-2
Hardware Error T
ypes and Remedies (continued)
Error T
ype:Name PriorityRemedySource
72 Protocol
Revision
Level Err
or
Namesend activity
Disable Namesend to the remote location.
1
Data-1
Digital Networking
Data-2
Local Protocol Revision Level
Data-3
Remote Protocol Revision Level
Data-4
Location number of Remote Location
73. Contr
ol Bus
Err
or – VCU
shar
ed RAM I/O
Dependent on value in
DATA-2.
Replace VCU. If error repeats, contact your
technical support center
.
3
Data-1
T
ask Number
Data-2 =01
VCU to CPU
=02
CPU to VCU
74
Gateway T
imeout
error
Message server timed
out waiting for the
gateway poll.
The OctelAccess server is not responding.
Check and bring up the OctelAccess server
.
3
Data-1
OctelAccess ID (the ID configured at the OctelAccess server)
75
Names Dir
ectory
Export err
or
Message server
detected error when
updating Names
Directory export file
or during export file
transfer.
Contact your technical support center
. 2
DATA-1 = ERROR CODE:
01 = NO DISK SPACE
02 = READ ONLY VOLUME
03 = ROOT DIRECTORY FULL
04 = NO SYSTEM DEVICE
05 = FILE CONTAINS BAD SECTORS
06 = NOT A FILE SYSTEM DRIVE